Sign In | Join Free | My disqueenfrance.com
China Xcell Energy  Equipment (Suzhou) Co., Ltd. logo
Xcell Energy Equipment (Suzhou) Co., Ltd.
Xcell Energy Equipment (Suzhou) Co., Ltd.
Verified Supplier

1 Years

Home > Cooling Tower Fills >

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

Xcell Energy Equipment (Suzhou) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

Brand Name : Xcell Energy

Model Number : XL-610-VF

Certification : SGS

Place of Origin : Jiangsu, China

MOQ : 1 Set

Price : Negotiated

Payment Terms : T/T

Supply Ability : 1000m2/per pay

Delivery Time : 7 Days

Packaging Details : Regular packaging/customizable

Condition : New

Cooling Type : Cooling Tower Parts

Material : PVC,PP,CPVC

Warranty : 1 Year

Name : Counter Flow 19mm Fluted PP Cooling Tower Filling, Cooling Tower Fill

Width : 1220/1830/2440/customized

Wave Height : 12/15/19/30mm

Usage : Cooing Tower

Thickness : 0.32-0.6mm

Contact Now

Counter Flow 19mm Fluted PP Cooling Tower Filling, Cooling Tower Fill

Description:

CounterFlow cooling tower packing features:

  • Good performance and high cooling efficiency. The filler is film type, and the protruding fine corrugations make the water contact surface larger. The filler is placed in 3~4 layers, and there is a redistribution process of hot water between the layers.
  • Good hydrophilicity and small ventilation resistance The filler with a rough and smoother surface has good hydrophilicity, and the water absorption rate is less than 0.015%, so that more water flow can form a film without splashing, so that water and air are more fully contacted At the same time, the surface disturbance of water and air is large when flowing.
  • The heat dissipation of the packing accounts for more than 85% of the entire temperature drop in the cross-flow tower. The heat dissipation process of the cooling tower is mainly carried out on the surface of the heat dissipation packing plate. The water film on the surface of the packing slowly flows down, and the inner water film is the high enthalpy humid air with a humidity of 100%, and the water molecules run from the high enthalpy area to the low enthalpy value. In the fresh air entering the tower, the enthalpy value of the air exiting the tower increases. As the concentration of water molecules decreases, the water molecules in the circulating hot water continuously evaporate from liquid to gaseous state, thereby taking away the latent heat of vapor. According to the above principles, the quality of the filler is the key to the cooling effect.

Specifications:

Tech Date
Sheet Width(mm) 305/610mm
Sheet Length 1220/1830/2440mm/customized
Thickness 0.32-0.6mm/customized
Sheet Spacing 12/15/19/30mm
Color grey/white/black
Material PP/PVC/CPVC

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

Cooling Tower Fill Operating of Principle

  • Cooling towers reject heat from water-cooled systems to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which is collected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.
  • There are two main configurations of factory assembled cooling towers: crossflow and counterflow. In crossflow cooling towers, the water flows vertically down the fill as air flows horizontally across. In counterflow cooling towers, the water flows vertically down the fill as air flows vertically up.

Related Cooling Tower Film Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

Supply in industry

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

How do fills work in the cooling tower?

Cooling towers reject heat from water-cooled system to the atmosphere. Hot water from the system enters the cooling tower and is distributed over the fill (heat transfer surface). Air is induced or forced through the fill, causing a small portion of the water to evaporate. This evaporation removes heat from the remaining water, which iscollected in the cold water basin and returned to the system to absorb more heat. Each cooling tower line, although operating under the same basic principle of operation, is arranged a little differently.

PACKING AND DELIVERY

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill

FAQ

Q: Are you trading company or manufacturer ?
A: We are manufacturer with our own factory.


Q: How long is your delivery time?
A: Generally it is 5-10 days if the goods are in stock. Or it is 15-20 days if the goods are not in stock, it is according to quantity.


Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge. And the freight cost will on the buyer's side.


Q: What is your terms of payment ?
A: Payment<=USD1000, 100% in advance. Payment>=USD1000, 30% T/T in advance ,balance before shipment.


Product Tags:

Fluted PP Cooling Tower Filling

      

19mm Cooling Tower Filling

      

Counter Flow Cooling Tower Fill

      
China 19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill wholesale

19mm Fluted PP Cooling Tower Filling Counter Flow Cooling Tower Fill Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xcell Energy Equipment (Suzhou) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0